DATAQ DI-710 General-purpose USB Data Acquisition System with Windaq software. Features 8 differential or 16 single-ended analog input channels, 4,000 Samples per second throughput, 14-bit measurement resolution, and full scale ranges of ±10mV, ±100mV, ±1V, ±10 V full scale.
The DI-710 Series of products is a family of instruments for general purpose and stand-alone data logger data acquisition applications. Options include interface type, input voltage range, and PC-connected or standalone data logger operation. Interface options are USB or Ethernet. Gain ranges have selectable factors per channel of 1, 2, 4, and 8, or 1, 10, 100, and 1000. Instruments with the stand-alone data logger option feature a built-in multimedia socket that accepts standard Secure Digital (SD) memories to which acquired data may be stored without a connected PC. SD memories are the same commonly available mass storage devices used with digital cameras and MP3 players. Memories ranging in size from 16 MB to 2 GB are supported. Instruments without this option must remain tethered to a PC’s USB or Ethernet port during data acquisition and use the PC’s own program and memory to store acquired data.
- Includes a DI-710-ULS instrument, a 6-foot USB cable, a power supply, a screwdriver for signal connections
- 16 single-ended, 8 differential analog inputs.
- Measurement range of ±10mV to ±10V
- Allows in-the-field measurements to be saved to Secure Digital (SD) cards, or stored to a PC in real time using WinDaq software
- 14-bit analog to digital conversion.
- Includes WinDaq Software.
- Record up to 14,400 Hz in stand-alone mode using high speed SD card
Specifications
Analog Inputs
- Number of Channels: 16SE/8DI (software selectable per channel)
- Measurement Range Full Scale:
- Input Impedance, single-ended: 1MΩ
- Input impedance, differential: 1MΩ each input to common
- Input bias current: 10µA for a 10V input, single channel
- Input offset voltage: Auto-zero
- Input offset current: 2nA (single channel)
- Max. normal mode voltage: 30V DC or peak AC
- Max. common mode voltage: 30V DC or peak AC
A/D Characteristics
- Type: Successive approximation
- Resolution: 14-bit
- Monotonicity: ±2 LSB
- Conversion Time: 69µs
Scanning Characteristics
- Max. throughput sample rate:
- Standard: 4,800 Hz (requires Unlock Code)
- Stand-alone: 14,400 Hz
- Min. throughput sample rate:
- Standard: 0.0034 Hz
- Stand-alone: 0.0017 Hz
Digital I/O
- Bits: 8 bidirectional bits
- Configuration: Each bit is programmable as Input or Output
- Output voltage levels:
- Min. “1” 3V @ 2.5mA sourcing
- Max. “0” 0.4V @ 2.5mA sinking
- Output current:
- Max. source, -2.5 mA
- Max. sink, 2.5mA
- Input voltage levels:
- Min. required “1” 2V
- Max allowed “0” 0.8V
Ethernet Interface
- Type: 10/100Base-T
- Connector: RJ-45
- Protocol: TCP/IP
- Server Type: DHCP
Removable Memory (Stand-alone models)
- Type: Standard SD (not SDHD or SDxC). Minimum speed of 13x. For sample rates above 2kHz SD speed should be 133x or higher.
- Capacity: 16 MB to 2 GB
Real Time Clock (Stand-alone models)
- Type: Date, hour, minute, second
- Resolution: 1 second
- Accuracy: 20 ppm
Indicators
- Stand-alone models: Three-color LED indicating Record, Standby, and Error conditions
- Standard models: Power LED
Transfer Rate to PC
- Real Time: up to 4,800 samples per second
- From Memory Card: up to 2,400 samples per second (Ethernet only)
Related Products
DI-710 General-purpose USB Data Acquisition System with Windaq software. Features 8 differential or 16 single-ended analog input channels, 4,000 Samples per second throughput, 14-bit measurement...
DI-710 General-purpose Ethernet Data Acquisition System with Windaq software. Features 8 differential or 16 single-ended analog input channels, 4,000 Samples per second throughput.
DI-710 General-purpose Ethernet Data Acquisition System with Windaq software. Features 8 differential or 16 single-ended analog input channels, 4,000 Samples per second throughput.
USB data acquisition system with stand-alone capability (records to SD card) featuring 8 inputs for DI-8B signal conditioning modules (not included), a maximum throughput rate...