DATAQ DI-2108-P High Speed USB Data Acquisition and Data Logger System with Windaq software and 32GB USB flash drive. Features 8 differential analog input channels, 16-bit measurement resolution, a full scale measurement ranges of ±2.5, ±5, ±10, 0-5, and 0-10 Volts, and stand-alone data recording to removable USB thumb drive. Includes a DI-2108-P instrument, a 6-foot USB cable, a screwdriver for signal connections, and a 32GB USB flash drive with WinDaq software.
Eight analog input channels provide differential measurement flexibility and programmable ±2.5, 5, 10 V bipolar and 0-5 and 0-10 V unipolar ranges per channel. The differential input configuration provides noise rejection, easily adapts to single-ended signal sources, and is protected up to ±150 V dc or peak ac so that inevitable measurement mishaps will not harm the instrument. The maximum sampling throughput rate of the DI-2108-P is 160 kHz.
7 digital ports, each configurable as an input or a switch. Input protection is provided to 25 V. When activated as inputs two ports allow dual functionality as discrete inputs, or programmed as a counter or rate input.
- Includes a DI-2108-P instrument, a 6-foot USB cable, a screwdriver for signal connections, and a 32GB USB flash drive containing WinDaq software
- Provided with WinDaq/Lite Software which records up to four channels at any sampling rate
- Stand-alone capability records data to USB thumb drive
- Up to 160 kHz sample throughput rate
- 16-bit analog-to-digital resolution
- Eight armored analog differential inputs
- Seven digital ports
Specifications
Analog Inputs
- Number of Channels: 8
- Configuration: Differential
- ADC Resolution: 16-bit
- Measurement range per channel: Programmable ±2.5, ±5, ±10, 0-5, 0-10 Volts
- Input impedance: 800 kΩ differential
- Dc accuracy: ±0.05% of range
- Common mode range: ±228 V dc or peak ac
Digital Ports
- Number of ports: 7
- Type: MOSFET switch
- Configuration: Programmable as digital input or
switch
Digital Ports Programmed as Switch
- Maximum drain voltage: 25 V
- Maximum sink current: 100 mA
Count/Rate
- Count: Port 2 configured as input
- Rate: Port 3 configured as input
- Maximum rate frequency: 50 kHz (20 kHz with a single enabled channel and 160 kHz sampling rate)
- Maximum count frequency: 50 kHz
Power consumption: <1.0 Watt, via USB interface
Interface: USB 2.0 (mini-B style connector)
Related Products
DI-1100 USB Data Acquisition starter kit with Windaq software. Features four differential analog input channels, 12-bit measurement resolution, and a full scale range of ±10V.
DI-2008 USB Thermocouple Data Acquisition system with Windaq software. Features 4 or 8 analog input channels programmable as a thermocouple or voltage input, 16-bit measurement...
DI-4108 High Speed USB Data Acquisition System with Windaq software. Features 8 differential analog input channels, 12 to 16-bit measurement resolution
DI-2108 High Speed USB Data Acquisition and Data Logger System with Windaq software and 32GB USB flash drive. Features 8 differential analog input channels.