Key Features:
- Demonstrates automatic control of level using proportional, proportional plus integral, and proportional, integral plus derivative (PID) control
- Uses industry-standard parts to make it ideal for industrial, vocational and academic training
- Demonstrates operation, calibration and tuning of controllers, transmitters, converters and valves
- Compact, mobile and fully self-contained
- Connects to the TE3300/03 Flow Process Training System for cascade control
- Connects to the TE3300/06 Computer Control System for distributed control
- Safe, practical and realistic
Description:
- The Level Process Training System is a compact and mobile unit for a wide range of experiments in flow control. It gives students a greater understanding of the stability of simple control systems
- The main parts of the Level Process Training system are:
- Industrial controller with auto-tune feature
- Two-channel chart recorder
- Current-to-pressure converter
- Differential pressure transmitter
- Transparent vessel
- Pneumatic control valve
- Three-speed pump
- Reservoir
- To carry out experiments, students fill the reservoir with clean water and prime the system. They then set the controller to regulate the flow of water using a pneumatic valve. This alters the water level in the transparent vessel.
The differential pressure transmitter connected to the vessel gives feedback to the controller. For a realistic experience, the equipment has industrial standard instrumentation and parts - The apparatus includes two gate valves. One valve controls the fl ow at the output (drain) and the other acts as a flow-bypass valve. A chart recorder shows and logs the changes of the process variable (level) and the
controller output.
Learning Outcomes:
- Proportional, integral and derivative control
- Setting up and demonstrating automatic control
- The principles of loop control and the calibration and tuning of controllers, transmitters, converters and valves
- Wet and dry leg operation of a differential pressure transmitter
- Operation of a level control system
- Cascade control of level and flow (when used with the TE3300/03 Flow Process Training System)
- Distributed control (when used with the TE3300/06 Computer Control System)
Specifications
Electrical supply:
- Single-phase 230 V at 0.3 A or 110 V at 0.6 A, 50/60 Hz (determined by order)
Dimensions and weight:
- 700 mm x 800 mm x 1750 and 120 kg
For details see the catalog below: