Absolute decay universal leak tester T8990-FORTEST

Brand: FORTEST
Product code: T8990

    A touch of innovation
    The new T8990 leak tester was designed to improve what was considered the best device in ForTest’s history, the M8990.
    The new video controller “ForTest MMI” brought a superior level of human-machine interaction, thanks to an innovative capacitive panel in tempered glass, around a splendid 6.2” colour display.
    Parameter programming is much faster thanks to the new numerical keyboard integrated in the menus, and the big display makes viewing even clearer of the test cycle.
    The main screen also enables interaction with shortcut functions, such as test program change, “smart” test archive menu and locking/unlocking using a password.

    Limitless connectivity.
    The new T8990 equipment includes ports for the USB slave, RS232, RS485, Profinet, EtherNet IP and EtherCAT. Assembly may also include an optional Ethernet port and a 26-pole connector with 4 inputs and 8 outputs, which are completely programmable, for interfacing with the external valves, safety barriers, switches, etc…
    The front panel has a master USB port assembled on it for connection to a USB key to save the tests conducted, backup/restore parameters and upgrade tool firmware.
    The connection to thermal printers, barcode/data-matrix readers and markers takes place automatically using an internal menu.

    Always better measurements.
    The test cycle was further accelerated thanks to processor and coprocessor interaction, maintaining the reliability that has always made ForTest unique.
    We can say with certainty that T8990 avails of the most advanced measurement section in the world, thanks to the centring technology in windows and the double Faraday optical-isolated cage, which reduces the settling times under 18 ms.
    This gives a real measurement resolution of 0.1 Pa at 1 bar (0.5 Pa at 6 bar), stable and noise-free.

    Optimised pneumatic section.
    Assembly of the latest generation solenoid valves has enabled a 30% increase in the filling speed compared to the previous model, maintaining reliability unaltered over time. Our tools do not require expensive maintenance in the pneumatic department. Actually, our objective is to make them increasingly reliable and long-lasting.

    Innovative design.
    What appears to be a simple design exercise, in fact hides an in-depth study to make use and understanding of the tool as simple as possible.
    The front panel is made of a single sheet of tempered glass and aluminium, which makes it extremely easy to clean, making the T8990 suitable for use in the laboratory and on the production line.
    The extensive internal menus are easy to understand and the graphic interface was designed to only display important information.
    Everything is exactly where it should be.

    Specifications

    Model 0-1bar 1-2bar 2-6bar 6-10bar 10-20bar 20-50bar
    Accuracy Dp 0,5% RDG+3DGT 0,5% RDG+3DGT 0,5% RDG+3DGT 0,5% RDG+3DGT 0,5% RDG+3DGT 0,5% RDG+3DGT
    Range of measurements Dp 0-65 mbar 0-65 mbar 0-65 mbar 0-650 mbar 0-650 mbar 0-650 mbar
    Resolution Dp 0,001 mbar 0,002 mbar 0,005 mbar 0,01 mbar 0,1 mbar 0,1 mbar
    Direct pressure accuracy 0,5%FS 0,5%FS 0,5%FS 0,5%FS 0,5%FS 0,5%FS
    Direct pressure measurement range 0-FS 0-FS 0-FS 0-FS 0-FS 0-FS
    Direct pressure resolution 0,1 mbar 0,1 mbar 0,1 mbar 1 mbar 1 mbar 10 mbar
    Accuracy measuring loss in cc/’ 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min
    Measurement range in cc/’ 0-10 cc/min 0-10 cc/min 0-10 cc/min 0-10 cc/min 0-10 cc/min 0-10 cc/min
    Measured measurement resolution in cc/’ 0,01 cc/min 0,01 cc/min 0,01 cc/min 0,01 cc/min 0,01 cc/min 0,01 cc/min
    Accuracy measure volume in cc 1%RDG+2cc 1%RDG+2cc 1%RDG+2cc 1%RDG+2cc
    Volume range in cc 0-500 cc 0-500 cc 0-500 cc 0-500 cc
    Volume measurement resolution in cc 0,1 cc/min 0,1 cc/min 0,1 cc/min 0,1 cc/min
    Measure unit mbar, bar, psi, mmHg, mmH2O, Pa, HPa, cc/min, cc/h, pressure/s.
    Dimensions 270X160X300 mm
    Weight 8 kg
    Display size 800×280 pixel
    Operating temperature range 5-40 °C
    RS232 ports 2
    RS485 ports 1
    “master” usb port 1
    “slave” usb port 1
    Ethernet port Optional
    I/O signals Start, Stop, Filling, Test, Good, Reject, 4BCD
    Auxiliary I/O signals (optional) 8 output programmable, 4 input programmable, 4BCD
    Number of programs 300
     Test archive memory Advanced
    Password block Yes
    Program name Yes , 16 characters
    Note The resolution to be considered for accuracy is always 1 Pa.

    Reference Normatives: EN 61010-1, EN61326-1 / EN61326/A1, EN61000-3-2 / EN61000-3-2/A14, EN61000-3-3 / EN61000-3-3/A1, EN61000-4-2 / EN61000-4-2/A1, EN61000-4-3 / EN61000-4-3/A1 / EN61000-4-3/A2, EN61000-4-4, EN61000-4-5, EN61000-4-11, EN1779

    • The resolution for uncertainty calculation is 1 Pa up to 10 bar.
    • The flow measurement of the flow meters is of mass type and referred to the reference condition of 0°C – 1013,25mbar.
    • Flow measurement of leak test equipment is volumetric.
    • Accuracy data are referred to and guaranteed under laboratory calibration conditions.
    • The accuracy of the flow measurement is referred up to 2 bar, for higher pressures variations are possible depending on the characteristics of the model.
    • For measurement scales greater than the limits indicated, the accuracy will be specified in the offer phase.